SYSTEM AND SUBSCRIBER MANAGER (SSM)
5-13
Revised August 2001
Part No. 002-3139-078
Participant - Locality/Home/Group entry in a Wide
Area Call.
Time-Out Behavior
Temporary
- When a participant is marked “tempo-
rary”, it is not loaded into a WAM until an actual
radio has transmitted on that Locality/Home/
Group. The participant then remains active for the
WAC Group Time-Out duration (in minutes). This
time-out timer is reset with each PTT on that
Locality/Home/Group. The timer value can be
changed for each Locality (default is 60 minutes)
and is located in the System Manager under the
Tools menu in the SSM (see Section 5.3.5).
Permanent
- When a participant is marked “perma-
nent”, it is loaded into a WAM regardless of
whether or not traffic has been seen for that partic-
ular Locality/Home/Group. When the WAC is
loaded into a WAM, all participants that are
marked as permanent are loaded into the WAM and
channels are brought up accordingly.
By Unique ID (pull-down)
- The time-out is from
the Permission Profile of the Unique ID. Permis-
sion Profiles are described in Section 5.3.2, and
they are assigned to Unique IDs as described in
Section 5.3.4.
Default Transmit UID - In the event that the WAM
does not have a UID available, the Default Unique ID
(loaded in the WAM) is used. The default is 8180 and
it is not recommended that it be changed as it ensures
that a UID is in the data base.
Default Priority - This is a take-over priority that is
used for allocating WAMs. When a call attempt is
made and the WAC has not yet been programmed into
a WAM, the Call Processor uses this priority to deter-
mine if a WAM is available. If the priority of the WAC
being taken over is equal or greater, then the
Maximum Inactive Time must have expired.
Maximum Inactive Time - The time (in seconds,
default is 10 seconds) that a Wide Area Call remains
reserved after a PTT and cannot be taken over by a
WAC of equal or lesser priority.
If the priority of the WAC being taken over is
less, then the Maximum Inactive Time does not matter.
However, there can be no active call (PTT) on the
WAM. Default priority is 5, with 1 being the highest.
Priority level 1 is reserved for emergency use only and
can be used to take over WACs regardless of whether
or not someone is talking on the WAM. Use of priority
level 1 as the default is not recommended and should
be reserved for emergency use only.
Hang Time - This is a time in seconds that the chan-
nels can be ordered to hang for a Group in the Wide
Area Call. This can be set from 0 - 7 seconds with the
default set to 0.
WAC Group Time-Out - This parameter is
programmed in the System Locality Manager screen
described in Section 5.3.5. It is a value in minutes that
a Temporary WAC participant remains active on a
Locality between PTTs. The Temporary participant is
not activated until a PTT is seen from that Group on
that Locality. The default is 60 minutes.
Routing Group - The Routing Group number corre-
sponds to the number assigned to WAMs (see Routing
Group in Section 6.4.13). NOTE: Do not use Routing
Group 0 because it is reserved for internal WAM use.
When configuring Wide Area Calls, it is important to
understand that by assigning a Routing Group to the
call, the scope of the call may be limited.
For example: In a four-switch system, if a call is
configured to use Routing Group 1 and the WAMs for
this Group only connect Switches 1 and 2, then the
call can never be activated in Switches 3 and 4 without
reconfiguration of the Routing Group.
Examples:
WAC with Permanent Participants
WAC ID 1 is set up with 3 participants. All
default values are chosen for WAC parameters.
Participant Locality Home Group Time-Out
Behavior
1 1 1 1 Permanent
2 2 1 1 Permanent
3 3 1 1 Permanent
When activated in a WAM, this call brings up all
three Localities if channels are available.